811A is direct-heated type thorium tungsten cathode high µ triode, can be used as high-frequency oscillation power amplification.
  		  			811 is similar to 811A, they can be exchanged each other.
  		  			 
  		  			Heater
  		  			Uf-----------------------6.3 V
  		  			If-----------------------4 A 
  		  			Maximum Rating
  		  			Ua-----------------------1250 V
  		  			Ia-----------------------125 mA
  		  			Pa-----------------------40W
  		  			grid current-------------50 mA
  		  			Operating frequency and Ua
  		  			When the operating frequency above 30MC, Ua and anode input power should be reduced as follows: 
  		  			Operating frequency(MC) Ua and anode input power
  		  			60 89%
  		  			80 70%
  		  			100 55%
  		  			 When it is in constant working, the anode should not be allowed to have slight red; when in interrupted working, it should only be allowed to have perceptible slight red.
  		  			Direct Interelectrode Capacitances 
  		  			Input--------------------5.5 PF
  		  			output-------------------0.6 PF
  		  			Grid to plate………………5.5 PF
  		  			 
  		  			Static parameter:
  		  			Ua……………………………2000 V
  		  			-Ug……………………………2 V
  		  			Ia……………………………26 mA
  		  			µ(Ia=20mA)…………………160
  		  			Maximum rating in other operating conditions
  		  			R-F power amplifier or oscillation, C amplifier (CW)
  		  			                                      CCS          ICAS
  		  			 Ua………………………1250         500    V
  		  			 Ia……………………….175           175    Ma
  		  			 Pa……………………….45             65     W
  		  			 Pa (in)………………. ..175           260     W
  		  			 Ug………………………-200         -200    V
  		  			 Ig………………………...55             50     mA
  		  			C amplifier anode-modulation, R-F power amplifier
  		  			                                        CCS       ICAS
  		  			Ua…………………………1000      1250  V
  		  			Ia…………………………..125        150   mA
  		  			Pa………………………….30           45    W
  		  			Pa (in)………………….....115        175    W
  		  			Ug…………………………-200        -200   V
  		  			Ig………………………...…50           50     mA
  		  			CCS: constant working 
  		  			ICAS: interrupted working 
  		  			 
  		  			A-F power amplifier or oscillation 
  		  			B amplifier, grid driving 
  		  			                                           Maximum  Rating
  		  			                                             CCS      ICAS 
  		  			Ua……………………………..1250   1500   V
  		  			Ia (max. sig)…………………..175     175    mA
  		  			Pa……………………………… 45      65     W
  		  			Pa (in) (max. sig)………… ...165      235    W
  		  			 
  		  			Recommended operating condition (Reference value)
  		  			(The value of two tubes) 
  		  			                                            CCS        ICAS
  		  			Ua……………………………1250        1500    V
  		  			Ug……………………………..0           -4.5       V
  		  			Ia (0)…………………………50           32        mA
  		  			Ia (max .sig)……………...…260          313      Ma
  		  			Ũg (pk)………………………145          170      V
  		  			Pd (max. sig)………………..3.8          4.4       W
  		  			RL (a-a)…………………… .12.4         12.4     kΩ